Home / Insights / Product Design and Discovery
Product Design and Discovery
Designing for Accessibility from the First Wireframe: A Practical WCAG 2.2 Checklist for Product Teams
Accessibility is far cheaper to design in than to retrofit. This guide shows where accessibility decisions are made at each design stage, what WCAG 2.2 means in practice for product teams, and how to test and hand off designs so developers can build them correctly.
TopicsProduct Design and DiscoveryQA and Software TestingWeb and SaaS Development
Key takeaways
- Most accessibility problems are introduced in design, not code: colour choices, missing labels, unclear focus order, small touch targets and interactions that rely on dragging or hovering.
- WCAG 2.2 organises its testable success criteria under four principles (perceivable, operable, understandable, robust) and three conformance levels; AA is the common target in contracts and procurement.
- Annotate designs for accessibility: headings, focus order, labels, error messages, and alternative text intentions belong in the handoff.
- Combine automated checks, manual keyboard and screen reader testing, and, where possible, sessions with users of assistive technology.
- Agree the target level and scope in writing at the start, so accessibility is part of acceptance criteria rather than a late surprise.
On this page
Accessibility often arrives late in a project: a customer’s procurement team sends a questionnaire, a public-sector tender requires conformance, or an audit flags issues just before launch. Fixing accessibility at that point means reworking components, redesigning colour palettes and rewriting flows that were already built.
Most of these problems were decided in design. Colour contrast, the order in which information is presented, how errors are communicated and whether an interaction can be completed without a mouse are all design decisions. This article sets out where those decisions sit, a practical checklist by stage, and how to test. It is written for product leads and designers working with development teams, and complements our guidance on UX audits and design systems, where accessible components pay off most.
WCAG 2.2 in brief
The Web Content Accessibility Guidelines (WCAG) are published by the W3C. Version 2.2 was published in October 2023. Its testable success criteria are grouped under four principles:
| Principle | What it means | Design examples |
|---|---|---|
| Perceivable | Information can be perceived in more than one way | Text alternatives for images, sufficient contrast, not relying on colour alone |
| Operable | Interface can be used with different input methods | Keyboard access, visible focus, adequate target size, alternatives to dragging |
| Understandable | Content and behaviour are predictable and clear | Clear labels, consistent navigation, helpful error messages |
| Robust | Works with current and future assistive technologies | Correct use of semantic elements, names and roles for custom components |
Success criteria fall into levels A, AA and AAA. Level AA is the level most commonly referenced in contracts and public-sector requirements. WCAG versions are backwards compatible: content that conforms to 2.2 also conforms to 2.1 and 2.0. Legal obligations vary by country and sector, so confirm the requirement that applies to your product with your legal or compliance advisers.
Discovery: decide the target and the audience
- Agree the target level, usually WCAG 2.2 AA, and which parts of the product it covers (public pages, logged-in app, admin tools, documents and emails).
- Identify users with specific needs. Older users in aged care, people with low vision, people using screen readers or switch devices, users with cognitive load in stressful contexts such as healthcare.
- Check platform obligations for mobile apps: both Apple and Google document accessibility features such as dynamic type and screen readers that users expect apps to support.
- Write accessibility into acceptance criteria so it is tested like any other requirement.
Wireframes and flows: structure decisions
Before visual design, the structure of a screen determines much of its accessibility.
- Heading hierarchy: each screen has a clear main heading and logical sub-headings that a screen reader user can navigate by.
- Reading and focus order: the order in which content is read and keyboard focus moves follows the visual and logical order.
- Landmarks: header, navigation, main content and footer regions are identifiable.
- Forms: every field has a visible label, related fields are grouped, and required fields are marked in text, not only by colour or an asterisk.
- Alternatives for complex interactions: drag-and-drop reordering, map selection or sliders have a simpler alternative such as buttons or input fields.
- Timeouts and multi-step flows: users can extend sessions, and steps do not require re-entering information unnecessarily.
Visual design: the common failure points
| Area | What to check | Common mistake |
|---|---|---|
| Colour contrast | Text and essential UI elements meet AA contrast ratios against their background | Light grey placeholder text and pale brand colours on white |
| Colour alone | Status, errors and chart series are distinguishable without colour | Red and green status dots with no icon or text |
| Focus indicator | Every interactive element has a clearly visible focus style | Focus outlines removed for aesthetic reasons |
| Target size | Interactive targets are large enough or adequately spaced | Small icon buttons packed together in tables and toolbars |
| Text resizing | Layouts work when text is enlarged or system font size increases | Fixed-height containers that clip text |
| Motion | Animations can be reduced and nothing flashes rapidly | Auto-playing carousels with no pause control |
| Error states | Errors describe the problem and how to fix it, next to the field | Generic “Invalid input” at the top of the form |
Building these rules into design tokens and components means every screen benefits automatically, which is why accessible design systems are so valuable.
Handoff: annotate for accessibility
Developers cannot infer accessibility intent from a static design. Annotate the Figma file or specification with:
- Heading levels for each text style used as a heading
- Focus order on complex screens, modals and multi-column layouts
- Accessible names for icon-only buttons (“Delete visit”, not “trash”)
- Alternative text intentions for images: descriptive, decorative or functional
- Error messages and live announcements, such as “3 results found” after filtering
- Behaviour of custom components: how a custom dropdown, date picker or tab set is operated by keyboard
- What happens at larger text sizes and on small screens
Review these annotations with engineers before build. Designers working alongside developers catches mismatches early.
Testing accessibility before release
| Method | What it finds | When |
|---|---|---|
| Design checks | Contrast, target size, labels, structure | During design reviews |
| Automated scanning in CI | Missing labels, contrast failures, invalid attributes | Every build |
| Manual keyboard testing | Focus traps, unreachable controls, illogical order | Each feature before release |
| Screen reader testing | Unclear names, missing announcements, confusing structure | Key journeys before release |
| Sessions with assistive technology users | Real-world barriers automated tools miss | Major releases or high-risk journeys |
Automated tools catch only part of the problem; many issues, such as whether alternative text is meaningful or focus order makes sense, need human judgement. Include accessibility checks in your regular QA process, as described in our guide to continuous testing.
Frequently asked questions
Which WCAG level should we aim for?
Level AA is the most common target in contracts and public-sector requirements. Some AAA criteria are worth adopting where they suit your users, but full AAA conformance is rarely required for whole products.
Does accessibility make products look plain?
No. Accessible design constrains some choices, such as very low-contrast text, but leaves plenty of room for brand and visual quality. Many accessible improvements, such as clearer labels and larger targets, help all users.
Can an existing product be made accessible?
Yes, usually in stages. Start with an audit of key journeys, fix shared components and design tokens first so improvements spread, then address individual screens by priority.
Do mobile apps follow WCAG?
WCAG principles apply to mobile, and many organisations use WCAG as their benchmark for apps. Apple and Google also provide platform-specific accessibility guidance and features that apps should support.
Sources and methodology
Guidance reflects PoliteTech delivery experience. The external references below informed specific points in this article.
- W3C Web Accessibility Initiative: WCAG 2 Overview — WCAG 2.2 publication date, the four principles, conformance levels A, AA and AAA, and backwards compatibility with 2.1 and 2.0.
Related reading
Continue your research
Do your designs meet the accessibility level your customers expect?
We design and annotate flows, prototypes and design systems with accessibility built in from the first wireframe. See Product Discovery and UI UX.